Lubrication Systems Lube Oil Systems
Trola-Dyne Lubrication Systems Lube Oil Systems
Custom Lubrication & Hydraulic Equipment
ISO 9001:2000 Registered Company
 
-------------------------------------------------------------------------------------------------------------
STANDARD LUBRICATION SYSTEM: DESIGN CRITERIA
-------------------------------------------------------------------------------------------------------------
The supplied components are assembled to provide a cost effective design with long lasting life and easy maintenance.

Max. Ambient Operating Temperature: 110 Deg. F
Oil Operating Temperature Range: 60 to 150 Deg. F
Lubricating Fluid (Oil):
(Mineral Based Fluids)
ISO 32 to 68 Viscosity Grade Oils
Maximum Oil Temperature Leaving Cooler: 110 to 150 Deg. F
Cooling Fluid (Water) Operating Temperature Range: Min. 40 Deg. F
Max. 85 Deg. F
Required Cooling Fluid (Water) Flow Rate: Equal to Design Oil Flow Rate
  Oil Pressure: Coolant Pressure:
Maximum Lube System Design: 100 Psig 120 Psig
System Proof: 200 Psig 150 Psig
Piping System Design: 115 Psig  
Oil Line Sizes: Maximum Fluid Velocities
Pressure Lines 10 Ft/Sec
Return Lines 2 Ft/Sec
Pump Suction 4 Ft/Sec
Reservoir Size:
Minimum Oil dwell time in the reservoir: 3 minutes
Plus Minimum air space Volume is: 10 per-cent Total Reservoir Size


-------------------------------------------------------------------------------------------------------------
STANDARD LUBRICATION SYSTEM: BASIC FEATURES
-------------------------------------------------------------------------------------------------------------
Component Description Material
Reservoir: Sloped bottom with drain shutoff valve; Segmented Tank with 40 micron Filler/breather, High level site-gauge Carbon Steel
Pump: Vertically mounted positive displacement screw type pump/motor assembly for easy access Cast Iron Housing & Hardened Steel Rotor
Pressure Relief Valve: SS Piston & Spring Cast Iron Housing
Oil Piping Carbon steel and ANSI Flange connections for customer connection; internal connections NPT  
Water Piping Connections Direct to cooler's Female NPT Ports  
Oil Cooler: Shell & Tube Oil to Water heat exchanger (4 or 2 Pass based on flow requirements) Cooling Water to pass thru the Tubes Brass Shell Brass Baffles Copper Tubes
Oil Filter Supplied with a high differential pressure bypass valve with easily replaceable 10 micron element plus dirty filter mechanical Indicator Aluminum Body Housing
Electric Motor 3500 RPM, 480 Vac 3 phase 60 Hz powered TEFC Housing, with SF 1.15 Heavy Duty Designed Housing
Pressure Gauge 2.5 Inch Dial size Accuracy 2% Stainless Steel
Oil Pressure Isolation Valves Bronze, Ball Valves  
Fluid Seals: Buna N (Max. Fluid Temperature: 200 Deg. F)  


TROLA-DYNE Assembly Details Heat Exchanger
Standard Lube System ISO 68 VG Max. Rated Oil Flow Rate Reservoir Size Reservoir Base; Foot **Print Size Assembly Nominal Dry Weight Pump Motor Size 85 Deg. F. Max Water Flow Rate Required Maximum Heat Transferred From Oil
Model No. GPM Gallons In. x In. Pounds Horsepower GPM BTU/Hr
2341-010-01 10 30 36 x 24 375 2 10 84,200
2341-020-01 20 60 48 x 27 550 5 20 167,900
2341-030-01 30 100 60 x 27 800 7.5 30 256,700
2341-040-01 40 120 60 x 30 975 10 40 357,900
2341-050-01 50 150 60 x 30 1100 10 50 415,500
2341-070-01 70 200 72 x 36 1675 15 70 575,200
2341-080-01 80 3250 72 x 36 1750 15 80 662,300
2341-100-01 100 300 72 x 36 2100 15 100 828,000
**This is the area of the Lube Oil Reservoir only, the actual size of the Lube assembly will be slightly larger.

>> View Hydraulic Schematic